PE Anti-Human CD24 Antibody

Product Details


CloneML5
ApplicationFlow Cytometry
ReactivityHuman
FormatPE
Target NameCD24, Ly-52, CD24 molecule; CD24A, heat-stable antigen (HSA)
IsotypeMouse IgG2a
Antibody TypeMonoclonal
Regulatory StatusRUO
FormulationPhosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and 0.2% (w/v) BSA
Protein ConcentrationSupplied at a lot-specific concentration.
Storage&HandlingThe antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Recommended UsageFor flow cytometric staining, it is recommended to use 5 µL of this reagent per 0.5-1.0 million cells in a 100 µL volume. Optimal reagent performance should be determined by titration for each specific application. PE has an excitation max at 565 nm and an emission max at 575 nm.
Excitation LaserBlue Laser (488 nm) Green/Yellow laser (532/561nm)
Isotype Controls301509
Antibody FamilyHuman Antibodies
Storage & HandlingThe antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
See All FormatsClone ML5

Background Information


Human CD24, also known as cluster of differentiation 24 or heat-stable antigen (HSA), is a small, highly glycosylated cell-surface protein involved in immune regulation, cell adhesion, and cellular signaling. It is expressed on various cell types, including B lymphocytes, granulocytes, monocytes, epithelial cells, and neural cells. CD24 contributes to immune cell activation and differentiation, regulates inflammatory responses, and participates in interactions between immune cells and their surrounding environment.



CD24 is encoded by the CD24 gene on chromosome 6q21. Its mature protein backbone consists of approximately 31–34 amino acids and is extensively modified by N-linked and O-linked glycosylation. These carbohydrate modifications contribute substantially to its molecular mass, typically approximately 35–45 kDa. Unlike conventional transmembrane proteins, CD24 lacks an intracellular signaling domain and is attached to the outer surface of the plasma membrane through a glycosylphosphatidylinositol (GPI) anchor. Its biological activity is largely mediated through interactions with other cell-surface molecules. Important binding partners include Siglec-10, P-selectin, and L1 cell adhesion molecule (L1CAM).



CD24 plays important roles in inflammatory regulation and cancer development. Its interaction with Siglec-10 on macrophages delivers an inhibitory signal that suppresses macrophage-mediated phagocytosis and helps protect cells from excessive inflammatory responses. However, many solid tumors, including breast, ovarian, lung, and colorectal cancers, overexpress CD24, exploiting this pathway as a "don't eat me" signal to evade immune surveillance. Elevated CD24 expression has also been associated with tumor progression, metastasis, and cancer stem-cell characteristics.



Therapeutically, CD24 represents a promising target for cancer immunotherapy. Blocking CD24–Siglec-10 interactions using monoclonal antibodies may enhance macrophage-mediated tumor clearance. Other investigational approaches include antibody–drug conjugates and CD24-directed CAR T-cell therapies. Modulating the CD24–Siglec pathway may also have potential in inflammatory and autoimmune diseases, although further clinical research is needed to establish its safety and effectiveness.

Isotype Control


PE Mouse IgG2a Isotype Control Antibody

Data Sheets


PE Anti-Human CD24 Antibody TDS

Related Protocols


Flow Cytometry Protocol

Frequently Asked Questions


How do I determine the optimal antibody concentration/titer for my experiment?
We recommend titrating each new antibody lot on your own cell type and instrument, since optimal concentration depends on cell density, target expression level, and cytometer sensitivity. Suggested starting dilutions or test sizes (e.g., µg or µl per 10^6 cells) are provided on the product page as a starting reference point, not a fixed requirement.

Can these antibodies be used for intracellular or intranuclear staining, or only surface staining?
Intended use (surface, intracellular, or both) is specified per product, indicated under Application. The appropriate Related Protocol is linked for each product. If you need to detect both surface and intracellular markers in the same panel, confirm each antibody's compatibility with your fixation/permeabilization protocol before combining them.

What controls should I use alongside these antibodies?
Matched isotype controls (same host species, isotype, and conjugate) are available for most clones to help distinguish specific binding from background/non-specific staining and are linked on each product page. Unstained, single-color compensation, and fluorescence-minus-one (FMO) controls are also recommended, especially for multicolor panel design.

Can I combine InnoCyto Flow Cytometry antibodies into a multicolor panel?
Yes — antibodies across our catalog are designed to be panel-compatible, and conjugate options are offered specifically to support multiplexing. When building a panel, pair bright fluorophores with low-expression targets, avoid excessive spectral overlap, and confirm compensation is set up correctly for your specific fluorochrome combination. Use our Panel Builder to simplify the process.

Have a product or application question? Consult our FAQs or contact us.